Poor flow to hydraulic motors can result in reduced performance and efficiency of the hydraulic system. There are several causes of poor hydraulic motor flow, and corresponding solutions to address them: 1. Insufficient liquid supply: Cause: If the pump of the hydraulic system does not provide enough flow, it may cause the hydraulic motor to perform poorly. Solution: Check the condition of the pump, make sure it is sized for the application, and verify it is running at the correct speed. If necessary, replace or repair pump. 2. Fluid contamination: Cause: Contaminants such as dirt, debris or moisture in the hydraulic fluid can restrict flow and cause poor performance. Solution: Implement a regular maintenance and filtration program to ensure hydraulic fluid remains clean. Install an appropriate filter and replace it according to the manufacturer's recommendations. 3. The hydraulic pipeline is blocked or restricted: Cause: An obstruction or restriction in the hydraulic lines may be preventing fluid flow to the motor. Solution: Check hydraulic lines for blockages, kinks, or restrictions and remove or replace any affected components. 4. Hydraulic system leakage: Cause: A hydraulic fluid leak may result in reduced flow because the system may not be able to maintain the necessary pressure. Solution: Identify and repair any leaks in the hydraulic system, including hoses, fittings, seals and connections. 90-M-100-NC-0-N-1-N-0-K3-W-00-NNN-00-00-F0 90M100NC0N1N0K3W00NNN0000F0 90-M-100-NC-0-N-1-N-0-S1-W-00-NNN-00-00-E6 90M100NC0N1N0S1W00NNN0000E6 90-M-100-NC-0-N-1-N-0-S1-W-00-NNN-00-00-F3 90M100NC0N1N0S1W00NNN0000F3 90-M-100-NC-0-N-1-N-0-S1-W-00-NNN-00-00-G0 90M100NC0N1N0S1W00NNN0000G0 90-M-100-NC-0-N-3-N-0-C7-W-00-NNN-00-00-F0 90M100NC0N3N0C7W00NNN0000F0 90-M-100-NC-0-N-3-N-0-C7-W-00-NNN-00-00-F3 90M100NC0N3N0C7W00NNN0000F3 90-M-100-NC-0-N-3-N-0-S1-W-00-NNN-00-00-F3 90M100NC0N3N0S1W00NNN0000F3 90-M-100-NC-0-N-7-N-0-C6-W-00-EBA-00-00-F0 90M100NC0N7N0C6W00EBA0000F0 90-M-100-NC-0-N-7-N-0-C6-W-00-NNN-00-00-F3 90M100NC0N7N0C6W00NNN0000F3 90-M-100-NC-0-N-7-N-0-C7-W-00-EAA-00-00-F3 90M100NC0N7N0C7W00EAA0000F3 90-M-100-NC-0-N-7-N-0-C7-W-00-EAA-00-00-G0 90M100NC0N7N0C7W00EAA0000G0 90-M-100-NC-0-N-7-N-0-C7-W-00-EBA-00-00-F0 90M100NC0N7N0C7W00EBA0000F0 90-M-100-NC-0-N-7-N-0-C7-W-00-EBA-00-00-F3 90M100NC0N7N0C7W00EBA0000F3 90-M-100-NC-0-N-7-N-0-C7-W-00-EEA-00-00-F0 90M100NC0N7N0C7W00EEA0000F0 90-M-100-NC-0-N-7-N-0-C7-W-00-EFA-00-00-F3 90M100NC0N7N0C7W00EFA0000F3 90-M-100-NC-0-N-7-N-0-C7-W-00-NNN-00-00-E6 90M100NC0N7N0C7W00NNN0000E6 90-M-100-NC-0-N-7-N-0-C7-W-00-NNN-00-00-F0 90M100NC0N7N0C7W00NNN0000F0 90-M-100-NC-0-N-7-N-0-C7-W-00-NNN-00-00-F3 90M100NC0N7N0C7W00NNN0000F3 90-M-100-NC-0-N-7-N-0-C7-W-00-NNN-00-00-G0 90M100NC0N7N0C7W00NNN0000G0 90-M-100-NC-0-N-7-N-0-C7-W-00-NNN-00-00-G3 90M100NC0N7N0C7W00NNN0000G3 5. Valve settings are incorrect: Reason: The hydraulic valve controlling the motor may be improperly adjusted, limiting the flow of the motor. Solution: Verify that the hydraulic valve is set correctly according to system requirements. Adjust valve settings as needed to provide proper flow. 6. Motor wear or damage: Cause: Over time, hydraulic motors wear out, reducing their efficiency and flow. Solution: If the motor is severely worn or damaged, it may need to be replaced. Regular maintenance and proper lubrication can extend the life of your motor. 7. Insufficient reservoir capacity: Cause: A hydraulic system with an undersized reservoir may not have enough fluid to adequately supply the motor. Solution: Increase the size of the hydraulic tank or ensure it is maintained at the proper level. 8. Insufficient hydraulic oil: Reason: Using the wrong type of hydraulic oil or hydraulic oil that does not meet system requirements can affect flow. Solution: Make sure the hydraulic fluid used is compatible with the system's specifications and temperature requirements. If the fluid does not meet these standards, replace the fluid. 9. Temperature effect: Reason: Extreme temperatures (too hot or too cold) can affect the viscosity of hydraulic fluid, causing flow problems. Solution: Use a hydraulic fluid suitable for the expected temperature range. Implement temperature control measures such as coolers or heaters as needed. 10. System design flaws: Cause: In some cases, poor flow can be the result of a hydraulic system design flaw, such as undersized components or incorrect component placement. Solution: Re-evaluate the hydraulic system design and, if necessary, consult a hydraulic system engineer to make appropriate design modifications. 90-M-100-NC-0-N-7-N-0-F1-W-00-EAA-00-00-F0 90M100NC0N7N0F1W00EAA0000F0 90-M-100-NC-0-N-7-N-0-F1-W-00-EBA-00-00-F3 90M100NC0N7N0F1W00EBA0000F3 90-M-100-NC-0-N-7-N-0-F1-W-00-EEA-00-00-F0 90M100NC0N7N0F1W00EEA0000F0 90-M-100-NC-0-N-7-N-0-F1-W-00-EFA-00-00-F0 90M100NC0N7N0F1W00EFA0000F0 90-M-100-NC-0-N-7-N-0-F1-W-00-NNN-00-00-F0 90M100NC0N7N0F1W00NNN0000F0 90-M-100-NC-0-N-7-N-0-F1-W-00-NNN-00-00-F3 90M100NC0N7N0F1W00NNN0000F3 90-M-100-NC-0-N-7-N-0-F1-W-00-NNN-00-00-G0 90M100NC0N7N0F1W00NNN0000G0 90-M-100-NC-0-N-7-N-0-K3-W-00-EEA-00-00-E4 90M100NC0N7N0K3W00EEA0000E4 90-M-100-NC-0-N-7-N-0-K3-W-00-NNN-00-00-F0 90M100NC0N7N0K3W00NNN0000F0 90-M-100-NC-0-N-7-N-0-S1-W-00-EBA-00-00-E6 90M100NC0N7N0S1W00EBA0000E6 90-M-100-NC-0-N-7-N-0-S1-W-00-EBB-00-00-F0 90M100NC0N7N0S1W00EBB0000F0 90-M-100-NC-0-N-7-N-0-S1-W-00-NNN-00-00-A3 90M100NC0N7N0S1W00NNN0000A3 90-M-100-NC-0-N-7-N-0-S1-W-00-NNN-00-00-E6 90M100NC0N7N0S1W00NNN0000E6 90-M-100-NC-0-N-7-N-0-S1-W-00-NNN-00-00-F0 90M100NC0N7N0S1W00NNN0000F0 90-M-100-NC-0-N-7-N-0-S1-W-00-NNN-00-00-F3 90M100NC0N7N0S1W00NNN0000F3 90-M-100-NC-0-N-7-N-0-T2-W-00-NNN-00-00-G0 90M100NC0N7N0T2W00NNN0000G0 90-M-100-NC-0-N-7-N-0-TJ-W-00-NNN-00-00-G0 90M100NC0N7N0TJW00NNN0000G0 90-M-100-NC-0-N-8-N-0-C6-W-00-EEA-00-00-A0 90M100NC0N8N0C6W00EEA0000A0 90-M-100-NC-0-N-8-N-0-C6-W-00-EFA-00-00-F3 90M100NC0N8N0C6W00EFA0000F3 90-M-100-NC-0-N-8-N-0-C6-W-00-NNN-00-00-E4 90M100NC0N8N0C6W00NNN0000E4 11. Trapped air: Reason: Air trapped in a hydraulic system compresses and reduces the effective flow of hydraulic oil. Solution: Bleed the hydraulic system to remove air bubbles and ensure the system is properly bled during maintenance or when new components are added. 12. Pressure relief valve settings: Reason: If the pressure relief valve is set too low, it will restrict flow to the motor by prematurely diverting fluid back to the reservoir. Solution: Adjust the pressure relief valve to the correct setting to ensure the motor receives the required pressure and flow. 13. Pump cavitation: Cause: When pump inlet pressure is low, cavitation can occur, causing bubbles to form in the fluid, reducing flow and damaging components. Solution: Address the cause of cavitation, which may be an undersized pump, clogged inlet, or fluid viscosity that is too high. Increase pump size, remove obstructions, or adjust fluid properties as needed. 14. Insufficient pump speed: Reason: If the hydraulic pump is not running at its intended speed, it may not be able to provide the required flow to the motor. Solution: Check the pump speed and make sure it meets the system requirements. If necessary, adjust pump speed. 15. Aging hydraulic oil: Reason: Over time, hydraulic fluid degrades, causing viscosity to increase and flow rates to decrease. Solution: Regularly monitor the condition of the hydraulic oil and change it at recommended intervals to maintain proper flow characteristics. 16.Hydraulic hose diameter: Reason: Using a hose with a diameter that is too small for the required flow rate will restrict the flow of fluid to the motor. Solution: Select hydraulic hoses with appropriate diameters to ensure they can handle the required flow without significant pressure drop. 90-M-100-NC-0-N-8-N-0-C6-W-00-NNN-00-00-E6 90M100NC0N8N0C6W00NNN0000E6 90-M-100-NC-0-N-8-N-0-C6-W-00-NNN-00-00-F0 90M100NC0N8N0C6W00NNN0000F0 90-M-100-NC-0-N-8-N-0-C6-W-00-NNN-00-00-F3 90M100NC0N8N0C6W00NNN0000F3 90-M-100-NC-0-N-8-N-0-C6-W-00-NNN-00-00-G0 90M100NC0N8N0C6W00NNN0000G0 90-M-100-NC-0-N-8-N-0-C6-W-00-NNN-00-00-G3 90M100NC0N8N0C6W00NNN0000G3 90-M-100-NC-0-N-8-N-0-C7-W-00-EAA-00-00-E4 90M100NC0N8N0C7W00EAA0000E4 90-M-100-NC-0-N-8-N-0-C7-W-00-EAA-00-00-G0 90M100NC0N8N0C7W00EAA0000G0 90-M-100-NC-0-N-8-N-0-C7-W-00-EAA-00-00-G3 90M100NC0N8N0C7W00EAA0000G3 90-M-100-NC-0-N-8-N-0-C7-W-00-EBA-00-00-E4 90M100NC0N8N0C7W00EBA0000E4 90-M-100-NC-0-N-8-N-0-C7-W-00-EBA-00-00-E6 90M100NC0N8N0C7W00EBA0000E6 90-M-100-NC-0-N-8-N-0-C7-W-00-EBA-00-00-F0 90M100NC0N8N0C7W00EBA0000F0 90-M-100-NC-0-N-8-N-0-C7-W-00-EBA-00-00-F3 90M100NC0N8N0C7W00EBA0000F3 90-M-100-NC-0-N-8-N-0-C7-W-00-EBA-00-00-G3 90M100NC0N8N0C7W00EBA0000G3 90-M-100-NC-0-N-8-N-0-C7-W-00-EEA-00-00-E4 90M100NC0N8N0C7W00EEA0000E4 90-M-100-NC-0-N-8-N-0-C7-W-00-EEA-00-00-F3 90M100NC0N8N0C7W00EEA0000F3 90-M-100-NC-0-N-8-N-0-C7-W-00-EEA-00-00-G0 90M100NC0N8N0C7W00EEA0000G0 90-M-100-NC-0-N-8-N-0-C7-W-00-EFA-00-00-A3 90M100NC0N8N0C7W00EFA0000A3 90-M-100-NC-0-N-8-N-0-C7-W-00-EFA-00-00-E6 90M100NC0N8N0C7W00EFA0000E6 90-M-100-NC-0-N-8-N-0-C7-W-00-EFA-00-00-F0 90M100NC0N8N0C7W00EFA0000F0 90-M-100-NC-0-N-8-N-0-C7-W-00-EFA-00-00-F3 90M100NC0N8N0C7W00EFA0000F3 17. Check valve problem: Reason: A faulty or improperly installed check valve can disrupt the flow of hydraulic oil. Solution: Check check valves for proper operation and make sure they are installed correctly in the hydraulic circuit. 18.Hydraulic system maintenance: Why: Neglecting regular maintenance can lead to a variety of problems, including poor flow. Solution: Implement a proactive maintenance program that includes inspections, fluid analysis, and component replacement as needed to prevent flow-related issues. 19.Load changes: Reason: Sudden or significant changes in hydraulic system load can affect flow. Solution: Make sure the hydraulic system is designed to handle varying loads and adjust settings as needed when load conditions change. Determining the specific cause of poor hydraulic motor flow often requires a systematic approach to troubleshooting, including inspection, testing, and possibly consultation with a hydraulic system specialist. Regular maintenance and following manufacturer guidelines are critical to preventing and resolving flow problems in hydraulic systems.

This article is published by the official website of Baolilai Hydraulics, please contact the author and indicate the source for reprinting:https://www.baolilai-pump.cn/news/1060.html

Tel:13600066458